Ada Door Requirements Push Side

Of 42 of wall to the handle side of the door then the min.
Ada door requirements push side. The push side of new swinging doors and gates that are within 10 inches of the finish floor or ground must have smooth surfaces. For a hinge side approach on the pull side of a swinging door there must be a min. This requirement appears in the manual doors section of both publications so it does not apply to automatic doors the purpose is to avoid projections that could catch a cane crutch walker or wheelchair and inhibit passage through the door opening so the requirement applies to the push side of the door only. Cavities created by added kick plates shall be capped.
Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop with the door open 90 degrees. Front approach push side with 42 min clr depth. Ada codes for doors and locks clear opening width 404 2 3 in order for wheelchairs to have clear passage through your doors at a minimum your clear opening width must be 32 wide. Openings more than 24 inches deep shall provide a clear opening of 36 inches minimum.
Parts creating horizontal or vertical joints in these surfaces shall be within 1 16 inch 1 6 mm of the same plane as the other. Clear width door openings shall provide a clear width of 32 inches minimum and a maximum of 48 inches. Swinging door and gate surfaces within 10 inches 255 mm of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door or gate. Clear width is measured from the face of the door to the stop when the door is fully opened at 90 degrees.
Accessible door front approach push side. Of 60 clear in front of the door and 36 of wall to the latch side of the door. Latch side clearance not only provides proper positioning at door hardware but also facilitates proceeding through doors against the force of. All doors in alcoves shall comply with the clearances for front approaches.
If there is a min. Hinge side approaches to push side of swinging doors if equipped with both latch and closer shall have maneuvering space of 54 inches 1370 mm minimum parallel to the doorway extending from the latch side to beyond the hinge side and 48 inches 1220 mm minimum perpendicular to the doorway. Maneuvering clearances at doors. Any spaces created by the addition of kick plates should be capped.
Depending on the direction of approach diagrams a through f illustrate minimum maneuvering space depths and latch side clearances for both push and pull sides of swinging sliding and folding doors. The 254 mm 10 in. These requirements do not apply to sliding doors and some tempered glass doors. The smooth surface should extend the full width of the door.